Extreme Networks ExtremeWare Version 7.8 Guía para resolver problemas

Busca en linea o descarga Guía para resolver problemas para Software Extreme Networks ExtremeWare Version 7.8. Extreme Networks ExtremeWare Version 7.8 Troubleshooting guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 122
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Extreme Networks, Inc.
3585 Monroe Street
Santa Clara, California 95051
(888) 257-3000
http://www.extremenetworks.com
Advanced System
Diagnostics and
Troubleshooting Guide
ExtremeWare Software Version 7.8
Published: May 2008
Part number: 100279-00 Rev 01
Vista de pagina 0
1 2 3 4 5 6 ... 121 122

Indice de contenidos

Pagina 1 - Troubleshooting Guide

Extreme Networks, Inc. 3585 Monroe Street Santa Clara, California 95051(888) 257-3000http://www.extremenetworks.comAdvanced System Diagnostics and Tro

Pagina 2

10 Advanced System Diagnostics and Troubleshooting GuidePrefaceRelated PublicationsThe publications related to this one are:• ExtremeWare Software Use

Pagina 3 - Contents

100 Advanced System Diagnostics and Troubleshooting GuideAdditional Diagnostics Toolslength. For example, a 2% error in the default value of the speed

Pagina 4 - Chapter 5 Diagnostics

Cable DiagnosticsAdvanced System Diagnostics and Troubleshooting Guide 101Extended Cable Status Information (Gigabit link established). When the Giga

Pagina 5

102 Advanced System Diagnostics and Troubleshooting GuideAdditional Diagnostics Tools

Pagina 6

Advanced System Diagnostics and Troubleshooting Guide 1037 Troubleshooting GuidelinesWhen a problem arises in the network, you should gather consisten

Pagina 7

104 Advanced System Diagnostics and Troubleshooting GuideTroubleshooting GuidelinesAsia TACAsia Pacific Rim, except Japan Located in Santa Clara, CA U

Pagina 8

What Information Should You Collect?Advanced System Diagnostics and Troubleshooting Guide 105What Information Should You Collect?• Mandatory technical

Pagina 9 - Conventions

106 Advanced System Diagnostics and Troubleshooting GuideTroubleshooting GuidelinesDiagnostic TroubleshootingFor “i” series switches, observe the foll

Pagina 10 - Related Publications

Extreme Networks’ RecommendationsAdvanced System Diagnostics and Troubleshooting Guide 107Extreme Networks’ RecommendationsExtreme Networks strongly r

Pagina 11 - 1 Introduction

108 Advanced System Diagnostics and Troubleshooting GuideTroubleshooting Guidelines2 Did the problem go away?If it did, monitor the operation of the s

Pagina 12 - Introduction

Using Memory Scanning to Screen I/O ModulesAdvanced System Diagnostics and Troubleshooting Guide 109Using Memory Scanning to Screen I/O ModulesNOTEMem

Pagina 13 - Supported Hardware

Advanced System Diagnostics and Troubleshooting Guide 111 IntroductionThis guide describes how to use the ExtremeWare hardware diagnostics suite to te

Pagina 14

110 Advanced System Diagnostics and Troubleshooting GuideTroubleshooting Guidelines

Pagina 15 - Diagnostics Support

Advanced System Diagnostics and Troubleshooting Guide 111A Limited Operation Mode and Minimal Operation ModeThis appendix describes two switch operati

Pagina 16 - The BlackDiamond Systems

112 Advanced System Diagnostics and Troubleshooting GuideLimited Operation Mode and Minimal Operation ModeTriggering Limited Operation ModeOn a BlackD

Pagina 17 - The BlackDiamond Backplane

Minimal Operation ModeAdvanced System Diagnostics and Troubleshooting Guide 113To detect a reboot loop, a timestamp and a counter are saved. Each time

Pagina 18 - BlackDiamond I/O Modules

114 Advanced System Diagnostics and Troubleshooting GuideLimited Operation Mode and Minimal Operation Mode

Pagina 19 - Management Switch Modules

Advanced System Diagnostics and Troubleshooting Guide 115B Reference DocumentsThis appendix lists additional documentation and other information resou

Pagina 20 - BlackDiamond MSM Redundancy

116 Advanced System Diagnostics and Troubleshooting GuideReference Documents• White papers and solutions documentation:— Advanced technologies— Applic

Pagina 21

Advanced System Diagnostics and Troubleshooting Guide 117IndexSymbols"e" series 13, 59, 101"hitless" MSM failover 21, 39"i&qu

Pagina 22 - Alpine Systems

118 Advanced System Diagnostics and Troubleshooting GuideIndexdefined 27error detection mechanisms 28fast-path checksum error 29fast pathchecksum erro

Pagina 23 - ” Series Systems

Advanced System Diagnostics and Troubleshooting Guide 119IndextBGTask 40, 41tConsole 41tEdpTask 40, 41tEsrpTask 40, 41tExcTask 41tExtTask 41tLogTask 4

Pagina 24

12 Advanced System Diagnostics and Troubleshooting GuideIntroductionDiagnostics: A Brief Historical PerspectiveDiagnostic utility programs were create

Pagina 25 - Detection

120 Advanced System Diagnostics and Troubleshooting GuideIndex

Pagina 26 - Definition of Terms

Advanced System Diagnostics and Troubleshooting Guide 121Index of CommandsAabort diagnostics cable 96, 97Cclear fdb remap 91clear log 93clear log d

Pagina 27 - Errors Between Wires

122 Advanced System Diagnostics and Troubleshooting GuideIndex of Commandsshow fdb remap 91, 106show log 72, 84, 91, 93, 105, 112, 113show packet-me

Pagina 28 - ASICASIC

Supported HardwareAdvanced System Diagnostics and Troubleshooting Guide 13• On-demand system hardware diagnostics—Run on demand through user CLI comma

Pagina 29

14 Advanced System Diagnostics and Troubleshooting GuideIntroduction

Pagina 30 - Soft-State Failures

Advanced System Diagnostics and Troubleshooting Guide 152 “i” Series Switch Hardware ArchitectureThis chapter provides a brief summary of the “i” seri

Pagina 31 - Permanent Failures

16 Advanced System Diagnostics and Troubleshooting Guide“i” Series Switch Hardware ArchitectureThe BlackDiamond SystemsIn the context of the advanced

Pagina 32

The BlackDiamond SystemsAdvanced System Diagnostics and Troubleshooting Guide 17The BlackDiamond BackplaneThe BlackDiamond backplane is a passive back

Pagina 33 - Alert Messages

18 Advanced System Diagnostics and Troubleshooting Guide“i” Series Switch Hardware ArchitectureBlackDiamond I/O ModulesEach BlackDiamond I/O module ha

Pagina 34 - Checksum Error Messages:

The BlackDiamond SystemsAdvanced System Diagnostics and Troubleshooting Guide 19packet memory for temporary storage. Based on the information in memor

Pagina 35 - Corrective Behavior Messages

2©2005 Extreme Networks, Inc. All rights reserved. Extreme Networks, ExtremeWare, Alpine, and BlackDiamond are registered trademarks of Extreme Networ

Pagina 36

20 Advanced System Diagnostics and Troubleshooting Guide“i” Series Switch Hardware ArchitectureBlackDiamond MSM RedundancyThe CPU subsystems on a pair

Pagina 37 - 4 Software Exception Handling

The BlackDiamond SystemsAdvanced System Diagnostics and Troubleshooting Guide 21The MSM failover behavior depends on the following factors:• Platform

Pagina 38 - Redundant MSM Behavior

22 Advanced System Diagnostics and Troubleshooting Guide“i” Series Switch Hardware ArchitectureAlpine SystemsLike the BlackDiamond systems, the Alpine

Pagina 39

Summit “i” Series SystemsAdvanced System Diagnostics and Troubleshooting Guide 23Summit “i” Series SystemsUnlike the BlackDiamond and Alpine systems,

Pagina 40 - Related Commands

24 Advanced System Diagnostics and Troubleshooting Guide“i” Series Switch Hardware Architecture

Pagina 41 - Usage Notes

Advanced System Diagnostics and Troubleshooting Guide 253 Packet Errors and Packet Error DetectionThis chapter describes some of the factors that migh

Pagina 42 - Software Exception Handling

26 Advanced System Diagnostics and Troubleshooting GuidePacket Errors and Packet Error DetectionDefinition of TermsTo establish a basis for the descri

Pagina 43

Standard Ethernet Detection for Packet Errors on the WireAdvanced System Diagnostics and Troubleshooting Guide 27Standard Ethernet Detection for Packe

Pagina 44

28 Advanced System Diagnostics and Troubleshooting GuidePacket Errors and Packet Error DetectionFigure 8: Generalized switch block diagramThe followi

Pagina 45 - ” Series Switch System Memory

Extreme Networks’ Complementary Detection of Packet Errors Between WiresAdvanced System Diagnostics and Troubleshooting Guide 29transmitted, but an in

Pagina 46

Advanced System Diagnostics and Troubleshooting Guide 3ContentsPrefaceIntroduction 9Terminology 9Conventions 9Related Publications 10Chapter 1 Introdu

Pagina 47

30 Advanced System Diagnostics and Troubleshooting GuidePacket Errors and Packet Error Detectiondescribed in the section “System (CPU and Backplane) H

Pagina 48

Failure ModesAdvanced System Diagnostics and Troubleshooting Guide 31Failures of this type are the result of software or hardware systems entering an

Pagina 49 - 5 Diagnostics

32 Advanced System Diagnostics and Troubleshooting GuidePacket Errors and Packet Error DetectionThe slow-path and fast-path categories each have a sep

Pagina 50 - Diagnostics

Health Check MessagesAdvanced System Diagnostics and Troubleshooting Guide 33The following examples describe how these values apply to a BlackDiamond

Pagina 51 - Diagnostic Test Functionality

34 Advanced System Diagnostics and Troubleshooting GuidePacket Errors and Packet Error DetectionThe intent of these messages is to alert the NOC that

Pagina 52 - Diagnostic Suite Components

Health Check MessagesAdvanced System Diagnostics and Troubleshooting Guide 35These messages appear in the log when EDP packets received are corrupted:

Pagina 53

36 Advanced System Diagnostics and Troubleshooting GuidePacket Errors and Packet Error DetectionThe PBUS checksum type might indicate a problem with t

Pagina 54 - Modes of Operation

Advanced System Diagnostics and Troubleshooting Guide 374 Software Exception HandlingThis chapter describes the software exception handling features b

Pagina 55

38 Advanced System Diagnostics and Troubleshooting GuideSoftware Exception HandlingThe system-watchdog feature is enabled by default. The CLI commands

Pagina 56

Overview of Software Exception Handling FeaturesAdvanced System Diagnostics and Troubleshooting Guide 39switch is equipped with MSM-64i modules), or 2

Pagina 57 - Runtime Diagnostics on “

4 Advanced System Diagnostics and Troubleshooting GuideContentsDefinition of Terms 26Standard Ethernet Detection for Packet Errors on the Wire 27Extre

Pagina 58

40 Advanced System Diagnostics and Troubleshooting GuideSoftware Exception HandlingConfiguring System Recovery ActionsExtremeWare provides a user-conf

Pagina 59

Configuring System Recovery ActionsAdvanced System Diagnostics and Troubleshooting Guide 41Configuring System Recovery Actions on “e” Series SwitchesT

Pagina 60 - ” Switches

42 Advanced System Diagnostics and Troubleshooting GuideSoftware Exception Handlingback into the network during a scheduled outage window. This might

Pagina 61

Configuring Reboot Loop ProtectionAdvanced System Diagnostics and Troubleshooting Guide 43Configuring Reboot Loop ProtectionReboot loop protection pre

Pagina 62

44 Advanced System Diagnostics and Troubleshooting GuideSoftware Exception HandlingOn BlackDiamond switches you can configure the number of times the

Pagina 63

Dumping the “i” Series Switch System MemoryAdvanced System Diagnostics and Troubleshooting Guide 45Dumping the “i” Series Switch System MemoryOn “i” s

Pagina 64 - Limited Operation Mode

46 Advanced System Diagnostics and Troubleshooting GuideSoftware Exception Handling• Configure the system dump as a system recovery response action.To

Pagina 65

Dumping the “i” Series Switch System MemoryAdvanced System Diagnostics and Troubleshooting Guide 47Example Log for a Software ExceptionThe following l

Pagina 66

48 Advanced System Diagnostics and Troubleshooting GuideSoftware Exception Handling

Pagina 67 - Switches

Advanced System Diagnostics and Troubleshooting Guide 495 DiagnosticsThis chapter describes how to configure and use the Extreme Advanced System Diagn

Pagina 68

Advanced System Diagnostics and Troubleshooting Guide 5ContentsThe Role of Processes to Monitor System Operation 55Power On Self Test (POST) 56Related

Pagina 69

50 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsSome diagnostic tests, such as the slot-based hardware diagnostics (including the p

Pagina 70 - Backplane Health Check States

Diagnostic Test FunctionalityAdvanced System Diagnostics and Troubleshooting Guide 51Diagnostic tests are processed by the CPU. When invoked, each dia

Pagina 71 - Auto-Recovery Response Action

52 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsFigure 10: Backplane health check paths (BlackDiamond architecture)System Health C

Pagina 72 - Backplane Health Check

System Health Checks: A Diagnostics SuiteAdvanced System Diagnostics and Troubleshooting Guide 53— Offer configurable levels— Remove the switch fabric

Pagina 73 - command

54 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsscanning and memory mapping diagnostics are used to identify and correct switch fab

Pagina 74

System Health Checks: A Diagnostics SuiteAdvanced System Diagnostics and Troubleshooting Guide 55Automatic Mode. Automatic mode for initiating a memo

Pagina 75

56 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsPower On Self Test (POST)The POST actually consists of two test processes: a “pre-P

Pagina 76 - I/O module slot

Runtime (On-Demand) System DiagnosticsAdvanced System Diagnostics and Troubleshooting Guide 57Runtime (On-Demand) System DiagnosticsThe ExtremeWare di

Pagina 77

58 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsBlackDiamond systems—whether the module type being tested is an MSM or an I/O modul

Pagina 78 - Analyzing the Results

Runtime (On-Demand) System DiagnosticsAdvanced System Diagnostics and Troubleshooting Guide 59System Impact of Running the Diagnostics on “i” Series S

Pagina 79 - CPU Health Check

6 Advanced System Diagnostics and Troubleshooting GuideContentsSystem Impacts of the Transceiver Diagnostics 83Network Impact of the Transceiver Diagn

Pagina 80

60 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsNOTEOnly run these diagnostics when the switch can be brought off-line. The tests p

Pagina 81

Automatic Packet Memory Scan (via sys-health-check)Advanced System Diagnostics and Troubleshooting Guide 61Automatic mode status is listed in the “sys

Pagina 82 - Transceiver Diagnostics

62 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsTable 7 describes the behavior of the switch if you run diagnostics manually on “i”

Pagina 83

Automatic Packet Memory Scan (via sys-health-check)Advanced System Diagnostics and Troubleshooting Guide 63Table 8 describes the behavior of the switc

Pagina 84 - Viewing Diagnostics Results

64 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsLimited Operation ModeA switch enters limited operation mode when some system healt

Pagina 85

Automatic Packet Memory Scan (via sys-health-check)Advanced System Diagnostics and Troubleshooting Guide 65During the memory scan, the CPU utilization

Pagina 86 - Example—show switch Command

66 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsInterpreting Memory Scanning ResultsIf single-bit permanent errors are detected on

Pagina 87

Per-Slot Packet Memory Scan on BlackDiamond SwitchesAdvanced System Diagnostics and Troubleshooting Guide 67Per-Slot Packet Memory Scan on BlackDiamon

Pagina 88 - FDB Scan

68 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsTo disable packet memory scanning on a BlackDiamond module and return to the behavi

Pagina 89 - Disabling FDB Scanning

Per-Slot Packet Memory Scan on BlackDiamond SwitchesAdvanced System Diagnostics and Troubleshooting Guide 69modules will trigger a reboot if the faile

Pagina 90

Advanced System Diagnostics and Troubleshooting Guide 7ContentsAsia TAC 104EMEA TAC 104Japan TAC 104What Information Should You Collect? 105Analyzing

Pagina 91

70 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsSystem (CPU and Backplane) Health CheckThe purpose of the system health check featu

Pagina 92

System (CPU and Backplane) Health CheckAdvanced System Diagnostics and Troubleshooting Guide 71Related Commandsenable sys-health-checkdisable sys-heal

Pagina 93

72 Advanced System Diagnostics and Troubleshooting GuideDiagnosticswhere:Alpine or Summit “i” series Switches. To configure the switch to respond to

Pagina 94 - Syslog Servers

System (CPU and Backplane) Health CheckAdvanced System Diagnostics and Troubleshooting Guide 73NOTEFrequent corrupted packets indicate a failure that

Pagina 95 - Adding a Syslog Server

74 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsBackplane Health Check Diagnostic Results—Example 1. Example 1 shows the report fr

Pagina 96

System (CPU and Backplane) Health CheckAdvanced System Diagnostics and Troubleshooting Guide 75To clarify the relationship between MSM ports, the back

Pagina 97 - Running Cable Diagnostics

76 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsBackplane Health Check Diagnostic Results—Example 2. Example 2 shows a report for

Pagina 98 - {detail}

System (CPU and Backplane) Health CheckAdvanced System Diagnostics and Troubleshooting Guide 77Backplane Health Check Diagnostic Results—Example 3. E

Pagina 99 - Cable Diagnostics

78 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsBackplane Health Check Diagnostic Results—Example 4. Example 4 shows a report for

Pagina 100 - Additional Diagnostics Tools

System (CPU and Backplane) Health CheckAdvanced System Diagnostics and Troubleshooting Guide 79• If a health check checksum error message appears in t

Pagina 101 - ” Series Switches

8 Advanced System Diagnostics and Troubleshooting GuideContents

Pagina 102

80 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsNOTEBe aware that the slot information in the log message might be symptomatic of a

Pagina 103 - 7 Troubleshooting Guidelines

System (CPU and Backplane) Health CheckAdvanced System Diagnostics and Troubleshooting Guide 81• CPU health check failures might indicate a faulty tra

Pagina 104 - Asia TAC

82 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsTransceiver DiagnosticsThe transceiver diagnostics test the integrity of the manage

Pagina 105 - Analyzing Data

Transceiver DiagnosticsAdvanced System Diagnostics and Troubleshooting Guide 83To configure the transceiver diagnostic threshold and window values, us

Pagina 106 - Diagnostic Troubleshooting

84 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsViewing Diagnostics ResultsUse the following commands to view information related t

Pagina 107 - Customer

Transceiver DiagnosticsAdvanced System Diagnostics and Troubleshooting Guide 85• CARD_HWFAIL_RR_SCNTRL_REG_TIMEOUT• CARD_HWFAIL_BLIZZARD_REGOP_TIMEOUT

Pagina 108 - Troubleshooting Guidelines

86 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsExample—show diagnostics command (Alpine system). The following example of the sho

Pagina 109

Transceiver DiagnosticsAdvanced System Diagnostics and Troubleshooting Guide 87License: Full L3 + Security...SysHealth Check: Enabled. A

Pagina 110

88 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsFDB ScanThe FDB scan diagnostic test addresses the possibility of hardware FDB memo

Pagina 111 - A Limited Operation Mode and

FDB ScanAdvanced System Diagnostics and Troubleshooting Guide 89The failure action that the FDB scan test performs depends on the sys-health-check com

Pagina 112 - Minimal Operation Mode

Advanced System Diagnostics and Troubleshooting Guide 9PrefaceThis Preface provides an overview of this guide, describes guide conventions, and lists

Pagina 113

90 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsConfiguring the FDB Scan Diagnostics• To set the interval between FDB scans, use th

Pagina 114

FDB ScanAdvanced System Diagnostics and Troubleshooting Guide 91Viewing Diagnostics ResultsUse the following commands to view information related to t

Pagina 115 - B Reference Documents

92 Advanced System Diagnostics and Troubleshooting GuideDiagnosticsIn the example output of the show diagnostics command, in those slots equipped with

Pagina 116 - Reference Documents

Advanced System Diagnostics and Troubleshooting Guide 936 Additional Diagnostics ToolsThis chapter describes additional diagnostic tools to detect and

Pagina 117

94 Advanced System Diagnostics and Troubleshooting GuideAdditional Diagnostics ToolsSystem Impacts of Temperature LoggingThe temperature logging featu

Pagina 118

Syslog ServersAdvanced System Diagnostics and Troubleshooting Guide 95Disabling Logging to Remote Syslog Server TargetsTo disable logging to all remot

Pagina 119

96 Advanced System Diagnostics and Troubleshooting GuideAdditional Diagnostics ToolsNetwork Impact of the Syslog Server FacilityNetwork impact depends

Pagina 120

Cable DiagnosticsAdvanced System Diagnostics and Troubleshooting Guide 97Running Cable DiagnosticsYou can run the CDM tests manually at any time, or y

Pagina 121 - Index of Commands

98 Advanced System Diagnostics and Troubleshooting GuideAdditional Diagnostics ToolsThe disable diagnostics cable command also purges the cable diagno

Pagina 122

Cable DiagnosticsAdvanced System Diagnostics and Troubleshooting Guide 99Following is sample detailed diagnostic output from this command:============

Comentarios a estos manuales

Sin comentarios