Altitude 4600 Series Access Point Installation Guide
15
1 Orient the unit on the wall by its width or length.
2 Using the arrows on one edge of the case as guides, move the edge to the midline of
the mounting area and mark points on the midline for the screws.
3 At each point, drill a hole in the wall, insert an anchor, screw into the anchor the
wall mounting screw and stop when there is 1mm between the screw head and the
wall.
When pre-drilling a hole the recommended hole size is 2.8mm (0.11in.) if the screws are
going directly into the wall and 6mm (0.23in.) if the provided wall anchors are being used.
4 If required, install and attach a security cable to the unit’s lock port.
5 Attach the Ethernet cable to the unit and to a controller with an 802.3af-compatible
power source.
6 Place the middle of each of the case’s mount slots over the screw heads.
7 Slide the case down along the mounting surface to hang the mount slots on the
screw heads.
8 Verify the unit has power by observing that the LEDs are lit or flashing.
Integrated Antenna Suspended Ceiling T-Bar Mount
Instructions
Ceiling mount requires holding the Altitude 4600 Series Access Point up against the T-
bar of a suspended ceiling grid and twisting the case onto the T-bar.