Extreme Networks e" series Guía de instalación Pagina 45

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 112
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 44
Port Connections
Consolidated "e" Series Hardware Installation Guide 45
On the Summit 200-24, ports 25 and 26 are the Gigabit Ethernet ports that have the redundant PHY
interfaces. On the Summit 200-48, it is ports 49 and 50. Each port has one mini-GBIC and 1000BASE-T
connection.
To set up a redundant link on either port 25 or on port 49, connect the active fibre and 1000BASE-T
links to both the RJ-45 and mini-GBIC interfaces of that port.
Summit 200-24 Switch Uplink Redundancy
Gigabit Ethernet uplink redundancy on the Summit 200-24 switch follows these rules:
Ports 25 and 26 are Gigabit Ethernet ports that have redundant PHY interfaces, one mini-GBIC and
one 1000BASE-T connection for each port.
Each of the uplink Gigabit Ethernet ports (25 and 26) can use either the mini-GBIC or the
1000BASE-T interface, but not both simultaneously.
Only one interface on each port can be active at a time. For example, on port 25, with both the
mini-GBIC and 1000BASE-T interfaces connected, only one interface can be activated. The other is
inactive. If both interfaces are connected, the switch defaults to the fiber interface (mini-GBIC) and
deactivates the 1000BASE-T interface.
If only one interface is connected, the switch activates the connected interface.
To set up a redundant link on port 25, connect the active fibre and 1000BASE-T links to both the
RJ-45 and mini-GBIC interfaces of port 25. The switch defaults to the fiber link. If the fiber link fails
during operation, the switch automatically activates the redundant 1000BASE-T link.
Summit 200-48 Switch Uplink Redundancy
Gigabit Ethernet uplink redundancy on the Summit 200-48 switch follows these rules:
Ports 49 and 50 are Gigabit Ethernet ports that have redundant PHY interfaces, one mini-GBIC and
one 1000BASE-T connection for each port.
Each of the uplink Gigabit Ethernet ports (49 and 50) can use either the mini-GBIC or
the1000BASE-T interface, but not both simultaneously.
Only one interface on each port can be active at a time. For example, on port 49, with both the
mini-GBIC and 1000BASE-T interfaces connected, only one interface can be activated. The other is
inactive. If both interfaces are connected, the switch defaults to the fiber interface (mini-GBIC) and
deactivates the 1000BASE-T interface.
If only one interface is connected, the switch activates the connected interface.
To set up a redundant link on port 49, connect the active fibre and 1000BASE-T links to both the
RJ-45 and mini-GBIC interfaces of port 49. The switch defaults to the fiber link. If the fiber link fails
during operation, the switch automatically activates the redundant 1000BASE-T link.
For information on the mini-GBIC, see “Evaluating and Meeting Mini-GBIC Requirements” on page 31.
NOTE
When configuring the Summit 200-48 switch, all ports specified as mirrored ports and mirroring port, or
ACL ingress ports and egress port, must belong to the same port group. Port group 1 consists of ports
1 through 24 and port 49; port group 2 consists of ports 25 through 48 and port 50.
Vista de pagina 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 111 112

Comentarios a estos manuales

Sin comentarios