Extreme Networks IP Service Manager Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 35
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
Deployment Guide ExtremeXOS, NetSight, NAC on BlackDiamond X8, BlackDiamond 8K, Summit Switches
© Extreme Networks, Inc. All rights reserved. 9
2. Manage the configurations and images using the commands:
save configuration
use image primary
download image
unconfig switch all
3. Reboot the system by typing reboot.
Basic Forwarding
This section is meant to be a starting point and represents only a tiny subset of the functionality
and options within EXOS. Please refer to ExtremeXOS documentation on the Extreme
documentation page for full descriptions.
Data Ports
By default, all ports are enabled and in the “Default” VLAN in the “VR-Default” VR, without any
Layer 2 protocol to prevent loops.
1. Disable all ports and then enable only the used ports. For example:
disable ports all
enable ports 1-3,5,7
2. Configure per-port “display-string” that is displayed on each of the show port CLI
commands, or “description-string” to modify SNMP alias. For example:
configure ports 8 display-string foo-display-string
configure ports 8 description-string "foo-description-string"
3. Configure the port speed. For example:
configure ports 1 auto off speed 10000 duplex full
4. Configure LAG ports. For example:
enable sharing 7 grouping 7-12,14 algorithm address-based L2 lacp
enable sharing 49 grouping 49, 53 algorithm address-based L3_L4 lacp
5. Use the following show commands to view the ports status. To clear the counters in the
show commands below, issue the command clear counters.
show ports information
show ports configuration
show ports statistics
show port sharing
show l2stats
show port rxerrors
show port packet
Vista de pagina 8