Extreme Networks ExtremeWare Enterprise Manager Guía de usuario Pagina 137

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 394
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 136
ExtremeWare EPICenter Software Installation and User Guide 5-35
Event Configuration
d Type“1500”intheRisingThreshold field.Notethat forthisvariablethevaluemust
be in hundredths of a percent.
e Type a smaller value, for example “1450” in the Falling Threshold field.
f Leave the SampleType as “Absolute” and theSample Interval at the default value
(15).
g Select Rising for the Startup Alarm field.
2 Click the Ta rget tab and do the following:
a Select Port as the Source Type
b Select “switch8” from the Device list
c Select 10 from the ifIndex list
d Click Add to add the port to the Selection list
3 Click the Apply button to configure the rule on device switch8.
A message window will appear with the device configuration results.
4 Verify that no switch configuration errors have been reported, and click OKto dismiss
the window.
5 Click Close to dismiss the New Configuration dialog.
Modifying a Rule
Once a set of RMON rules have been created, they must be modified individually. To
modify a RMON rule do the following:
1 SelecttherulefolderortheindividualrulenameintheConfigurationstreetodisplay
the rule details in the main panel of the window.
2 Select the individual rule you want to modify
3 Click the Modify button at the top of the page.
The Modify Configuration window is displayed for the target you selected.
Vista de pagina 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 393 394

Comentarios a estos manuales

Sin comentarios