Extreme Networks ExtremeWare Enterprise Manager Guía de usuario Pagina 326

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 394
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 325
ExtremeWare EPICenter Software Installation and User Guide 16-11
Viewing Predefined EPICenter Reports
conditional statement based on the values of relevant variables in the ExtremeWare
EPICenter database.
The following reports provide filtering:
Interface Report
Alarm Log
Event Log
Config Mgmt Log
These reports provide a set of fields at the bottom of the report similar to the ones shown
in Figure 16-3.
Figure 16-3: Report filter specification
To create a filter, follow these steps:
1 In thefirst field,selectthe variableto use in thefilter.Thevariables from which youcan
choose are based on the column headings in the report, and depend on the type of
report you are viewing.
2 In the second field, select a comparison operator. You canchoose from the following
comparison operators:
> (greater than)
<(lessthan)
<= (greater than orequal)
>= (less than or equal)
!= (not equal)
=(equal)
Vista de pagina 325
1 2 ... 321 322 323 324 325 326 327 328 329 330 331 ... 393 394

Comentarios a estos manuales

Sin comentarios