160 ExtremeWare Error Message Decoder
Critical Messages
Corrupted Packets on Slot
Sys-health-check [DIAG] First 16 bytes of unknown pkt on slot 9
Software Version
ExtremeWare 6.2 and later
Hardware Version
BlackDiamond, Alpine, and Summit
Explanation
CPU diagnostics has detected corrupted packets on slot 9.
Action
Run Show Diagnostics, and then compare the output with log message. If the counter is increasing
rapidly, isolate the module.