Extreme Networks ExtremeWare Version 7.8 Especificaciones Pagina 619

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 978
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 618
Invalid Time Values
ExtremeWare Error Message Decoder 619
Invalid Time Values
<WARN:STP> decode_bpdu, received time values out of range "max age" "hello time"
"forward delay"
Software Version
ExtremeWare 6.2.2 or later
Hardware Version
All
Explanation
This message indicates that there are invalid STP timer values in the received BPDU.
Action
1 Capture the incoming STP BPDU and analyze the fields.
2 Check the STP timer configuration of the neighbor switches.
3 If the values are out of range, then correct the values.
Vista de pagina 618
1 2 ... 614 615 616 617 618 619 620 621 622 623 624 ... 977 978