586 ExtremeWare Error Message Decoder
Warning Messages
Diagnostic Failure, Slot
<WARN:PORT> MAC Chip of slot 3 port 1 is not ready
<WARN:PORT> init internal receive TOS look-up table failed on slot 3 port 1!
<WARN:PORT> init MAC Id look-up table failed on slot 3 port 1!
<WARN:PORT> init internal App Rec look-up table failed on slot 3 port 1!
<WARN:PORT> init App Cmp internal look-up table failed on slot 3 port 1!
<WARN:PORT> init Vlan Rec look-up table failed on slot 3 port 1!
<WARN:PORT> init Vlan Cmp look-up table failed on slot 3 port 1!
Software Version
ExtremeWare 6.1.x
Hardware Version
BlackDiamond
Explanation
These messages indicate a problem in reading the port (port 1 on slot 3) since it can not be initialized.
Action
Run diagnostics. If diagnostics fail, RMA the module.