Vista de pagina 884
Link Down PDU Not Processed
ExtremeWare Error Message Decoder 885
Link Down PDU Not Processed
Not processing Link-Down-Pdu, because linkId %d matches our own
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” series
Explanation
The message indicates that the link-down-pdu was not processed because the link-id of the
link-down-pdu matches the link-id of the EAPS super domain (ESD) instance.
This also indicates that the link-down-pdu is from a neighbor and the shared port of the neighbor is
down. The EAPS process already learnt this information.
Action
Informational only. No action needed.