650 ExtremeWare Error Message Decoder
Warning Messages
Port Not in VLAN
<WARN:EAPS> eaps_runtime.c 1222: Warning! Port (1:1) not in vlan "v1"
Software Version
ExtremeWare 6.2.2 or later
Hardware Version
All
Explanation
This message indicates that the port selected to send out the EAPS PDU has not been added to the
control VLAN. The PDU cannot be sent.
Action
Configure the EAPS control VLAN correctly by adding both the ring-ports to it as tagged ports.
Vista de pagina 649