910 ExtremeWare Error Message Decoder
Informational Messages
EAPSD: State Transition to Up, from Blocked
EAPS: EAPSD eaps2a - 1:1 state transition from Blocked => Up
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” and “e” series
Explanation
The message indicates that the port has moved from the blocking state to UP.
In EAPS master node, if the primary and secondary ports are up, the secondary port will be in blocking
state. When the primary port goes down, the secondary port is moved from the blocking state to UP
state or open state.
In EAPS transit node, if the transit node detects that a failed links has moved to up state, the node will
put the port in blocking state until it gets a Flush PDU from the master node.
Action
Check the links status in EAPS ring.