Vista de pagina 920
EAPSD: State Transition to Failed, from Init
ExtremeWare Error Message Decoder 921
EAPSD: State Transition to Failed, from Init
EAPS: EAPSD eaps-up - State transition from Init => Failed
Software Version
ExtremeWare 7.2 and later
Hardware Version
All “i” and “e” series
Explanation
This message indicates that the EAPS master has moved to Failed state from Init state.
EAPS master moves to failed state from init state if:
The EAPS master receives Link-Down PDU from the Transit switches.
The EAPS master receives Ring-port Down from lower layers
The Fail timer expired because the switch did not receive the HealthCheck PDU.
The EAPS master can be in any of the following states:
INIT
IDLE
FAILED
COMPLETE
Action
Check the ring port status in the EAPS ring.