Extreme Networks Summit WM Series Guía de usuario Pagina 201

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 228
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 200
Major
Summit WM-Series WLAN Switch and Altitude Access Point Software Version 1.0 User Guide
201
CDR_COLLECTOR
ACCESSPOINT
Severity Major
Log Message Beacon Creation Problem. Cannot allocate beacon.
Description Beacon Creation Problem.
Action Upgrade AP with the proper latest software.
CDR_COLLECTOR
Severity Major
Log Message Internal messaging error: %d. Accounting information for one client session will be
incomplete.
Description Accounting record is incomplete for a single client session.
Action A single accounting record is incomplete. To accurately bill for usage, the client session
needs to be audited against the RADIUS accounting server.
CDR_COLLECTOR
Severity Major
Log Message Can not create new CDR record for session%d. Accounting record for one client session will
be unavailable.
Description Transient error condition while creating an accounting record.
Action A single accounting record is incomplete. To accurately bill for usage, the client session
needs to be audited against the RADIUS accounting server.
CDR_COLLECTOR
Severity Major
Log Message Error will be ignored and message re-tried.
Description Error sending message on the system messaging infrastructure.
Action Recoverable messaging error; the process will recover. Monitor for future occurrences, and
contact support if the problem persists.
CDR_COLLECTOR
Severity Major
Log Message Internal messaging error:%d. Error will be ignored and message re-tried.
Description Process could not connect to internal messaging infrastructure.
Action Recoverable messaging error; the process will recover. Monitor for future occurrences, and
contact support if the problem persists.